This threaded stud DIN 976-1 has metric M8 thread and a length of 120 mm, made of stainless steel A4 (AISI 316) in class A4-70. Pitch 1.25 mm, thread along the full length. Weight about 0.04 kg per piece (0.33 kg/m).
What it is used for
Joints with two nuts or a coupling nut where a bolt is too short or not available: through-fixings in beams and profiles, spacers, extending suspensions, anchoring in a chemical anchor. The chamfered ends let the nut start easily. Stainless A4 also resists chlorides: coast, pools, marine and industry.
What it is not suited for
Not as a high-strength preloaded structural joint: class 8.8/10.9 bolts are meant for that.
Dimensions and strength
DIN 976-1 covers threaded rods with continuous thread: form A are rods of 1 m, 2 m or 3 m, form B are studs cut to length with chamfered ends. Pitch and thread to ISO 261. Class A4-70: tensile strength 700 N/mm², yield 450 N/mm² (ISO 3506-1); stress area M8 = 36.6 mm², giving a breaking load of about 25.6 kN per rod (not an allowable load: apply a safety factor).
| size | pitch P | As | weight/m (steel) | breaking load A4-70 |
|---|
| M3 | 0.5 mm | 5.03 mm² | 0.045 kg | 3.5 kN |
| M4 | 0.7 mm | 8.78 mm² | 0.08 kg | 6.1 kN |
| M5 | 0.8 mm | 14.2 mm² | 0.125 kg | 9.9 kN |
| M6 | 1 mm | 20.1 mm² | 0.185 kg | 14.1 kN |
| M8 | 1.25 mm | 36.6 mm² | 0.33 kg | 25.6 kN |
| M10 | 1.5 mm | 58 mm² | 0.52 kg | 40.6 kN |
| M12 | 1.75 mm | 84.3 mm² | 0.77 kg | 59 kN |
| M14 | 2 mm | 115 mm² | 1.05 kg | 80.5 kN |
| M16 | 2 mm | 157 mm² | 1.38 kg | 109.9 kN |
| M18 | 2.5 mm | 192 mm² | 1.73 kg | 134.4 kN |
| M20 | 2.5 mm | 245 mm² | 2.15 kg | 171.5 kN |
| M22 | 2.5 mm | 303 mm² | 2.68 kg | 212.1 kN |
| M24 | 3 mm | 353 mm² | 3.14 kg | 247.1 kN |
| M27 | 3 mm | 459 mm² | 4.07 kg | 229.5 kN |
| M30 | 3.5 mm | 561 mm² | 4.92 kg | 280.5 kN |
| M33 | 3.5 mm | 694 mm² | 6.05 kg | 347 kN |
| M36 | 4 mm | 817 mm² | 7.2 kg | 408.5 kN |
Cutting and fitting
Run a nut onto the rod first, cut with a hacksaw or cutting disc, deburr and run the nut off so the thread is clean again. Fit with a DIN 934 nut and DIN 125 washer on both sides. Join two rods in line with a DIN 6334 coupling nut M8: screw each rod in at least 12 mm. As an anchor rod in a chemical anchor (vinylester): drill 10 mm, embedment about 80 mm as a guide value, brush and blow out the hole, inject the mortar and insert the rod with a turning motion; curing and loads per the anchor data sheet. Tighten stainless gently and use anti-seize paste for stainless on stainless.
Frequently asked questions
What is the difference between DIN 976 and DIN 975? DIN 975 was the old standard for 1 m threaded rods; DIN 976-1 replaces it and adds form B (studs cut to length). Sizes and thread are the same.
Which nut fits it? A DIN 934 M8 hexagon nut and a DIN 125 M8 washer in the same material.
How much tensile load can this rod take? The breaking load is about 25.6 kN (stress area 36.6 mm² × 700 N/mm²). That is the load at which the rod breaks; apply a safety factor for the design load and follow the anchor data sheet for anchoring.
Can I use this rod in a chemical anchor? Yes, M8 is a common anchor size: drill 10 mm and set the rod about 80 mm deep in vinylester injection mortar (guide value, see the anchor data sheet).
Can I use it outdoors? Yes, also near the coast and at swimming pools.
Dimensions to DIN 976-1 / ISO 261, class to ISO 3506-1. Last checked on 10 November 2026.